Ps programme scanner, Programme scanner – Avery Dennison Monarch 9864 Description of Commands User Manual
Page 64

10/07 Rev. AA
MANUAL EASY PLUG
Commands
All
devices
A = TTX 600 --TLX 604 – Eagle B = TTX 300 Offline -- Cobra Offline D = TTX 300 Online –TTX 207 -- Cobra Online – Da Capo
E = TTX 450/650/674/675/950/1050 – Puma/Puma plus/Lion/Lion plus/Tiger/Tiger XXL -- S45/65/95/105 -- TDI/STDI/XXTREME
G = TTX 350 – Ocelot – TTK – Texxtile H = 64-xx –Chess x –TT4 – DPM – PEM – ALX 92x – AP 4.4/5.4
64
#PS
Programme scanner
Definition
The scanner is programmed with the special command #PS. A maximum of
8 codes (n = 8) can be programmed on one label. This number must
correspond to at least the number of activated codes (a, b, c etc.).
The command must stand outside of the command sequence #ER to #Q!
The sequences STX (02h), ETX (03h) and EOT (04h) may not be used in
the code.
Syntax
#PSa/w/b/x/c/y/d/z/n
Groups
E
a, b, c, d = int
Easy Plug bar code number (0 to 4, 7 to 9, 13, 16)
w, x, y, z = int
Number of characters in the bar code (0 = variable bar code length)
n = int
Number of codes on the label
The following bar codes are supported:
Barcode
Easy Plug
number
Number for
scanner
no code
EAN-8
0
0
EAN-13
1
1
UPCA
2
2
Code 93
3
3
2/5I
4
4
Code 39 (2:1)
7
7
Codabar
8
8
UPCE
9
9
Code 128
13
13
EAN 128
15
13
Code 39 (3:1)
16
7
Code 128 (UPS)
18
13
Code 39 (1,5:1)
19
7
Code 2/5 i (1:3)
20
4
Code 128 A
24
13
Code 128 B
25
13
Code 128 C
26
13
Code 128 Pharmacy
27
13
If several codes of the same type (of the same or any length) are to be
printed on one label, it is only necessary to activate the code once and to
enter the appropriate number of codes with n.