beautypg.com

Avery Dennison Monarch 9864 Description of Commands User Manual

Page 22

background image

10/07 Rev. AA

MANUAL EASY PLUG

Commands

All

devices

A = TTX 600 --TLX 604 – Eagle B = TTX 300 Offline -- Cobra Offline D = TTX 300 Online –TTX 207 -- Cobra Online – Da Capo
E = TTX 450/650/674/675/950/1050 – Puma/Puma plus/Lion/Lion plus/Tiger/Tiger XXL -- S45/65/95/105 -- TDI/STDI/XXTREME
G = TTX 350 – Ocelot – TTK – Texxtile H = 64-xx –Chess x –TT4 – DPM – PEM – ALX 92x – AP 4.4/5.4

22

Parameter

No. of digits

Example

Allocation / Unit

Ribbon autoecon.

1

„0“

0 = Deactivated
1 = Activated
2 = Thermal printing

Ribbon eco. limit

6

„10.0“

mm

Turn on mode

1

„0“

0 = Offline
1 = Online

Single job mode

1

„0“

0 = Deactivated
1 = Activated

Head resistance

4

„1244“

Ohm

Temp. reduction

2

„50“

%

Voltage offset

3

„10“ ,“-20“

%

Singlestartquant

2

„1“

Punch search qt.

2

„3“

Mat. end detect

1

„0“

0 = Deactivated
1 = Activated

Periph device

1

„1“

0 = None
1 = Cutter
2 = Rewinder
3 = Tear-off edge
4 = Dispenser

External signal

1

„0“

0 = Disabled
1 = Single start
2 = Stacker full

Signal edge

1

„0“

0 = Falling edge
1 = Rising edge

Print contrast

3

„65“

%

Ram disc size

4

„128“

KByte

Font downl. area

4

„256“

Kbyte

Language

1

„0“

0 = German
1 = English
2 = French

Signal / buzzer

1

„1“

0 = Off
1 = On

Access authoriz.

1

„0“

0 = Deactivated
1 = Power-up code
2 = User
3 = Supervisor

Monitor version

10

„2.2a“

Driver version

10

„1.0.2.3“

Number of digits:

182