Olvd define olv limits, Olvd, Define olv limits – Avery Dennison Monarch 9864 Description of Commands User Manual
Page 58

10/07 Rev. AA
MANUAL EASY PLUG
Commands
All
devices
A = TTX 600 --TLX 604 – Eagle B = TTX 300 Offline -- Cobra Offline D = TTX 300 Online –TTX 207 -- Cobra Online – Da Capo
E = TTX 450/650/674/675/950/1050 – Puma/Puma plus/Lion/Lion plus/Tiger/Tiger XXL -- S45/65/95/105 -- TDI/STDI/XXTREME
G = TTX 350 – Ocelot – TTK – Texxtile H = 64-xx –Chess x –TT4 – DPM – PEM – ALX 92x – AP 4.4/5.4
58
#OLVD Define OLV limits
Definition
Definition of limits for the separate readability criteria. Is only valid for RJS
SV100 OLV.
For every bar code may be defined a separate limit.
Command must stand between #ER and #Q!
Syntax
#OLVD/a/b/c/d/e/f/g/h/i/j/k/u
Group
H
a
=
P
Decodable
(Pass)
= F
Not decodable (Fail)
b
=
0...100
Decodability
c
=
0...100
Modulation
d
=
0...100
Defects
e
=
0…100
Edge
contrast
f
=
0...100
Rmin/Rmax
g
=
0...100
Symbol
contrast
h
=
0…100
PCS
i
=
0...100
R
(white)
j
=
0...100
R
(black)
k
=
0...99
Ratio
u = 0...40 ANSI symbol grade
The measured value must in all cases be above or equal the set limit.
For detailed information please read the SV100 manual.
Example
#OLVD//45//20/////////
Only „Decodability“ and „Defects“ is