beautypg.com

Info: parameter types, Sp stop printing, Stop printing – Avery Dennison Monarch 9864 Description of Commands User Manual

Page 15

background image

10/07 Rev. AA

MANUAL EASY PLUG

Commands

All

devices

A = TTX 600 --TLX 604 – Eagle B = TTX 300 Offline -- Cobra Offline D = TTX 300 Online –TTX 207 -- Cobra Online – Da Capo
E = TTX 450/650/674/675/950/1050 – Puma/Puma plus/Lion/Lion plus/Tiger/Tiger XXL -- S45/65/95/105 -- TDI/STDI/XXTREME
G = TTX 350 – Ocelot – TTK – Texxtile H = 64-xx –Chess x –TT4 – DPM – PEM – ALX 92x – AP 4.4/5.4

15

INFO: Parameter types

The printer provides 4 parameter types, whose setting range and
assignment can be queried.

Integer parameter

(e.g.

PRINTER PARAMETER > Bar code Multip.

)

Integer value; must match the setting range.

Example

Setting range: 1024-65535
Unit interval: 1

Float parameter

(e.g.

PRINTER PARAMETER > Print speed

)

Value with decimal places; must match the setting range.

Example

Setting range: 0.0-999.9
Unit interval: 0.1

String parameter

(e.g.

INTERF.PARAM. > ETHERNET PARAM. >

FTP password

)

Example

Maximum string length: 16 characters

Discrete parameter

(e.g.

SYSTEM PARAMETER > Periph. device

)

Integer value with a special meaning.

Example

0 = RS232
1 = RS422
2 = RS485

#!SP

Stop printing

Definition

Stops the printing of a label series.

Printing of a label is completed. This command is ignored if the printer is
already on stand-by (finished or no #Q). Data from the spooler (queue) is
not evaluated. Only immediate commands are processed.

Syntax

#!SP

All

groups

#!SP =

Stops the printing:

– Labels being printed are completed

– Series is halted

– Spooler is no longer processed

– Printing process only restarts after the printer receives a start command

#!SR.