Info: parameter types, Sp stop printing, Stop printing – Avery Dennison Monarch 9864 Description of Commands User Manual
Page 15

10/07 Rev. AA
MANUAL EASY PLUG
Commands
All
devices
A = TTX 600 --TLX 604 – Eagle B = TTX 300 Offline -- Cobra Offline D = TTX 300 Online –TTX 207 -- Cobra Online – Da Capo
E = TTX 450/650/674/675/950/1050 – Puma/Puma plus/Lion/Lion plus/Tiger/Tiger XXL -- S45/65/95/105 -- TDI/STDI/XXTREME
G = TTX 350 – Ocelot – TTK – Texxtile H = 64-xx –Chess x –TT4 – DPM – PEM – ALX 92x – AP 4.4/5.4
15
INFO: Parameter types
The printer provides 4 parameter types, whose setting range and
assignment can be queried.
Integer parameter
(e.g.
PRINTER PARAMETER > Bar code Multip.
)
Integer value; must match the setting range.
Example
Setting range: 1024-65535
Unit interval: 1
(e.g.
PRINTER PARAMETER > Print speed
)
Value with decimal places; must match the setting range.
Example
Setting range: 0.0-999.9
Unit interval: 0.1
String parameter
(e.g.
INTERF.PARAM. > ETHERNET PARAM. >
FTP password
)
Example
Maximum string length: 16 characters
(e.g.
SYSTEM PARAMETER > Periph. device
)
Integer value with a special meaning.
Example
0 = RS232
1 = RS422
2 = RS485
#!SP
Stop printing
Definition
Stops the printing of a label series.
Printing of a label is completed. This command is ignored if the printer is
already on stand-by (finished or no #Q). Data from the spooler (queue) is
not evaluated. Only immediate commands are processed.
Syntax
#!SP
All
groups
#!SP =
Stops the printing:
– Labels being printed are completed
– Series is halted
– Spooler is no longer processed
– Printing process only restarts after the printer receives a start command
#!SR.