beautypg.com

Bch bar code height factor, Bof spooler buffer off, Bon spooler buffer on – Avery Dennison Monarch 9864 Description of Commands User Manual

Page 24: Bar code height factor, Spooler buffer off, Spooler buffer on

background image

10/07 Rev. AA

MANUAL EASY PLUG

Commands

All

devices

A = TTX 600 --TLX 604 – Eagle B = TTX 300 Offline -- Cobra Offline D = TTX 300 Online –TTX 207 -- Cobra Online – Da Capo
E = TTX 450/650/674/675/950/1050 – Puma/Puma plus/Lion/Lion plus/Tiger/Tiger XXL -- S45/65/95/105 -- TDI/STDI/XXTREME
G = TTX 350 – Ocelot – TTK – Texxtile H = 64-xx –Chess x –TT4 – DPM – PEM – ALX 92x – AP 4.4/5.4

24

B

#BCH Bar code height factor

Definition

This command is used for magnifying the height of the bar code.

The factor relates to the height defined in the command

#YB

. This

command may only be sent outside of a format #ER to #Q/.

Syntax

#BCHn

Group

D

n = int

Bar code height factor (1 to 10).

Default value is "1". The bar code height factor is stored in the NOVRAM.

Example

#BCH5

A bar code EAN 8 10 mm high
multiplied by the factor "5" is
transformed into a bar code 50 mm
high.

#ER ...

#YB0/0/9////12345678

#BOF

Spooler buffer off

Definition

This command is used to block the interface spooler buffer. The spooler
buffer is blocked after receiving a format, and is only released after the
required number of labels has been printed.

The #BOF command is not saved in Groups A and B, i.e. this command
only remains active until the printer has been switched off or until a #BON
command is sent.

The command must stand outside of the command sequence #ER to #Q!

Syntax

#BOF

All

groups

#BOF =

Spooler buffer works in single job mode. Only one format can be sent.

#BON Spooler buffer on

Definition

This command is used to activate the interface spooler buffer. It releases
the spooler buffer after it has been blocked (with #BOF).

In this mode several formats can be sent to the spooler (even during the
printing phase).

In Groups A and B the printer is always in BON mode after it is switched
on.

The command must stand outside of the command sequence #ER to #Q!

Syntax

#BON

All

groups

#BON =

Spooler buffer works in multi-job mode. Formats can be sent at all times.