E-stop configuration utility, E-stop verification utility – Adept s600 Cobra User Manual
Page 66

Chapter 5: Maintenance
E-Stop Configuration Utility
This utility sets the E-Stop hardware delay to factory specifications.
NOTE: Ensure that the commissioning jumper is plugged into the XBELTIO jack on
the eAIB before you start this procedure.
Procedure
From within the Adept ACE software:
1. Open the robot object editor.
2. Select Configure > Safety Settings > Configure ESTOP Hardware Delay, then click
Next.
This procedure will configure Channel A and then Channel B.
It will then report the delay that it set for each.
3. Reboot the SmartController.
On some systems, the SmartController will reboot automatically.
4. Reboot the eAIB.
E-Stop Verification Utility
This utility verifies that the hardware E-Stop parameters are set correctly and that the
hardware E-Stop is working.
The hardware E-Stop must have already been configured for this wizard to run.
NOTE: If the commissioning jumper is plugged into the XBELTIO jack on the eAIB,
remove it before you start this procedure.
Procedure
From within the Adept ACE software:
1. Open the robot object editor.
2. Select Configure > Safety Settings > Verify ESTOP Hardware Delay, then click Next.
3. Enable high power, if not already enabled, then click Next.
4. Press an E-Stop button (on the Front Panel), then click Next.
The utility will confirm that the hardware delay has been verified for this robot, and
display the delay times for channels A and B.
5. Reboot the SmartController.
On some systems, the SmartController will reboot automatically.
Adept Cobra s600/s800 Robot, User’s Guide, Rev L1
Page 66 of 128