Chapter 3: System Installation

E

E

N

L3

L

L1

L2

F5 10A

F4 10A

Adept Cobra
s600/s800 and
i600/i800Robots
1Ø 200–240VAC

User-Supplied
AC Power Cable

Note: F4 and F5 are user-supplied, must be slow blow.


200–240VAC

L = Line 1
N = Line 2
E = Earth Ground

200–240VAC

Figure 3-4. Single-Phase Load across L1 and L2 of a Three-Phase Supply

NOTE: If a three-phase power source is used, it must be symmetrically-earthed
(with grounded neutral). Connections called out as single-phase can be wired Line-
to-Neutral or Line-to-Line.

Details for AC Mating Connector

The AC mating connector is supplied with each system. It is typically shipped in the
cable/accessories box. The supplied plug is internally labeled for the AC power connections (L,
E, N).

Table 3-7. AC Mating Connector Details

AC Connector details

AC in-line power plug,
straight, female, screw
terminal, 10 A, 250 VAC

Qualtek P/N 709-00/00

Digi-Key P/N Q217-ND

The AC power cable is not supplied with the system, but is available in the
optional Power Cable kit; see Table 3-1.

Creating the 200-240 VAC Cable

1. Locate the AC mating connector shown in the previous table.

2. Open the connector by unscrewing the screw on the shell and removing the cover.

3. Loosen the two screws on the cable clamp. See Figure 3-5.

4. Use 18 AWG wire to create the AC power cable. Select the wire length to safely reach

Adept Cobra s600/s800 Robot, User’s Guide, Rev L1