Chapter 4: System Operation

The displayed fault code will continue to be displayed even after the fault is corrected or
additional faults are recorded. All displayed faults will be cleared from the display, and reset
to a no-fault condition, upon successfully enabling high power to the robot, or power cycling
the 24 V supply to the robot.

Figure 4-2. Status Panel

Table 4-2. Status Panel Codes

LED

Status Code

LED

Status Code

OK

No Fault

H#

High Temp Encoder (Joint #)

ON

High Power ON Status

hV

High Voltage Bus Fault

MA

Manual Mode

I#

Initialization Stage (Step #)

24

24 V Supply Fault

M#

Motor Stalled (Joint #)

A#

Amp Fault (Joint #)

NV

Non-Volatile Memory

B#

IO Blox Fault (Address #)

P#

Power System Fault (Code #)

AC

AC Power Fault

PR

Processor Overloaded

D#

Duty Cycle Exceeded (Joint #)

RC

RSC Fault

E#

Encoder Fault (Joint #)

S#

Safety System Fault (Code #)

ES

E-Stop

SE

E-Stop Delay Fault

F#

External Sensor Stop

SW

Watchdog Timeout

FM

Firmware Mismatch

T#

Safety System Fault
(Code 10 + #)

FW

IEEE 1394 Fault

TR

Teach Restrict Fault

h#

h# High Temp Amp (Joint #)

V#

Hard Envelope Error (Joint #)

For more information on status codes, go to the Adept Document Library on the Adept website,
and in the Procedures, FAQs, and Troubleshooting section, look for the Adept Status Code
Summary
document.

Adept Cobra s600/s800 Robot, User’s Guide, Rev L1