beautypg.com

8 connecting 200-240 vac power to robot – Adept s600 Cobra User Manual

Page 31

background image

Chapter 3: System Installation

+

24V, 8A

Frame Ground

24V, 5A

+

User-Supplied
Power Supply
24 VDC

Adept Cobra
s600/s800 Robot

User-Supplied Shielded
Power Cable

-

+

Adept SmartController

User-Supplied Shielded
Power Cable

Attach shield from user-supplied
cable to side of controller using
star washer and M3 x 6 screw.

Attach shield from user-
supplied cables to frame
ground on power supply.

Attach shield from user-
supplied cable to ground
screw on Cobra s600/s800
Interface Panel.

GND

+

Figure 3-2. User-Supplied 24 VDC Cable

NOTE: In order to maintain compliance with standards, Adept recommends that
DC power be delivered over a shielded cable, with the shield connected to frame
ground at both ends of the cable.

3.8 Connecting 200-240 VAC Power to Robot

WARNING: Appropriately sized Branch Circuit
Protection and Lockout / Tagout Capability must be
provided in accordance with the National Electrical Code
and any local codes.Ensure compliance with all local
and national safety and electrical codes for the
installation and operation of the robot system.

Adept Cobra s600/s800 Robot, User’s Guide, Rev L1

Page 31 of 128

This manual is related to the following products: