background image

Chapter 4: System Operation

Typical Output Wiring Example

M

Adept-Supplied Equipment

User-Supplied Equipment

Outputs 1-8

Typical User Loads

XIO Connector – 26-Pin Female D-Sub

+24VDC

19

Signal 0097

20

Signal 0098

21

Signal 0099

22

Signal 0100

23

Signal 0101

24

Signal 0102

25

Signal 0103

26

Signal 0104

GND

GND

Load

1

Customer
AC Power
Supply

10

M

Load

Load

L

N

(equivalent
circuit)

Wiring
Terminal
Block

Figure 4-6. Typical User Wiring for XIO Output Signals

XIO Breakout Cable

The XIO Breakout cable is available as an option—see the following figure. This cable connects
to the XIO connector on the AIB/eAIB, and provides flying leads on the user’s end, for
connecting input and output signals in the workcell. The cable length is 5 M (16.4 ft).

For the wire chart on the cable, see the following table.

NOTE: This cable is not compatible with the XIO Termination Block.