Chapter 5: maintenance, 1 field-replaceable parts, 2 periodic maintenance schedule – Adept s600 Cobra User Manual
Page 55

Adept Cobra s600/s800 Robot, User’s Guide, Rev L1
Page 55 of 128
Chapter 5: Maintenance
5.1 Field-replaceable Parts
WARNING: Only qualified service personnel may install
or service the robot system.
The following parts are the only field-replaceable parts:
Table 5-1. Field-replaceable Parts
Part
Adept Part Number
Encoder battery
09977-000 (3.6 V, 6.8 Ah)
(This has replaced part number 02704-000)
AIB (Amp-In-Base)
04900-000
eAIB (Amp-In-Base)
s600
s800
19800-600
19800-800
These parts must only be replaced with the Adept part numbers in the preceding table.
5.2 Periodic Maintenance Schedule
The following table gives a summary of the preventive maintenance procedures and
guidelines on frequency.
Also, for cleanroom robots, see Cleanroom Maintenance on page 125; for IP-65 robots, see
Customer Requirements on page 116.
Table 5-2. Inspection and Maintenance
Item
Period
Reference
Check E-Stop, enable and key
switches, and barrier interlocks
6 months Checking Safety Systems on page 56
Check robot mounting bolts
6 months Checking Robot Mounting Bolts on page 56
Check for signs of oil around
of harmonic drive area.
3 months Checking for Oil Leakage on page 56.
Lubricate Joint 3 (Z-axis) ball
screw
3 months Lubricating Joint 3 on page 57
Replace encoder battery
5 to 10
years