beautypg.com

Chapter 5: maintenance, 1 field-replaceable parts, 2 periodic maintenance schedule – Adept s600 Cobra User Manual

Page 55

background image

Adept Cobra s600/s800 Robot, User’s Guide, Rev L1

Page 55 of 128

Chapter 5: Maintenance

5.1 Field-replaceable Parts

WARNING: Only qualified service personnel may install
or service the robot system.

The following parts are the only field-replaceable parts:

Table 5-1. Field-replaceable Parts

Part

Adept Part Number

Encoder battery

09977-000 (3.6 V, 6.8 Ah)
(This has replaced part number 02704-000)

AIB (Amp-In-Base)

04900-000

eAIB (Amp-In-Base)

s600

s800

19800-600

19800-800

These parts must only be replaced with the Adept part numbers in the preceding table.

5.2 Periodic Maintenance Schedule

The following table gives a summary of the preventive maintenance procedures and
guidelines on frequency.

Also, for cleanroom robots, see Cleanroom Maintenance on page 125; for IP-65 robots, see
Customer Requirements on page 116.

Table 5-2. Inspection and Maintenance

Item

Period

Reference

Check E-Stop, enable and key
switches, and barrier interlocks

6 months Checking Safety Systems on page 56

Check robot mounting bolts

6 months Checking Robot Mounting Bolts on page 56

Check for signs of oil around
of harmonic drive area.

3 months Checking for Oil Leakage on page 56.

Lubricate Joint 3 (Z-axis) ball
screw

3 months Lubricating Joint 3 on page 57

Replace encoder battery

5 to 10
years

Replacing the Encoder Battery Pack on page 68

This manual is related to the following products: