Specifications for AC Power
Table 3-5. Specifications for 200/240 VAC User-Supplied Power Supply
Auto-Ranging
Nominal
Voltage
Ranges
Minimum
Operating
Voltage
a
Maximum
Operating
Voltage
Frequency/
Phasing
Recommended
External Circuit
Breaker,
User-Supplied
200 V to 240 V
180 V
264 V
50/60 Hz
1-phase
10 Amps
a
Specifications are established at nominal line voltage. Low line voltage can affect robot
performance.
Table 3-6. Typical Robot Power Consumption
Cobra Robot
Move
Average
Power (W)
RMS Current
(A)
Peak Power
(W)
a
s600
No load—Adept cycle
b
344
1.56
1559
5.5 kg—Adept cycle
b
494
2.25
2061
5.5 kg—all joints move
880
4.00
2667
s800
No load—Adept cycle
b
377
1.71
1406
5.5 kg—Adept cycle
b
531
2.41
1955
5.5 kg—all joints move
794
3.61
2110
a
For short durations (100 ms).
b
For details on Adept cycle, see Robot Specifications on page 108.
NOTE: The Adept robot system is intended to be installed as a piece of equipment
in a permanently-installed system.
WARNING: Adept systems require an isolating
transformer for connection to mains systems that are
asymmetrical or use an isolated (impedant) neutral.
Many parts of Europe use an impedant neutral.
DANGER: AC power installation must be performed by
a skilled and instructed person—refer to the
Adept Robot
Safety Guide
. During installation, unauthorized third
parties must be prevented from turning on power
through the use of fail-safe lockout measures.