beautypg.com

3 xsys/xsystem connector – Adept s600 Cobra User Manual

Page 107

background image

Chapter 7: Technical Specifications

7.2 Cobra s600/s800 Robot Internal E-STOP Connections

Cobra s600/s800

Internal Connections

SmartController
Connections

Force-Guided Relay
Cyclic Check
Control Circuit

Force-Guided

Force-Guided

Single-Phase
AC Input
200-240 VAC

High Power to
Amplifiers

Man 1
Man 2

Auto 1
Auto 2

XSLV-2 (XSYSTEM 8)
XSLV-3 (XSYSTEM 38)
XSLV-6 (XSYSTEM 14, 29)
XSLV-7 (XSYSTEM 30, 44)

ESTOPSRC

ESTOPGND

HPWRREQ

XSLV-9 (XSYSTEM 16)

XSLV-1 (XSYSTEM 17)

XSLV-5 (XSYSTEM 34)

To XSYS on
SmartController

Figure 7-9. Internal E_STOP Connections Diagram

7.3 XSYS/XSYSTEM Connector

Table 7-1. XSYS to XSYSTEM Connector Pinout (eAIB only)

XSYS
Pin #

XSYSTEM

Pin #

Description

Comment

Pin Location

1

17

ESTOP_GND

E-Stop system Ground

2

8

ENABLE_SW_1-

3

38

ENABLE_SW_2-

4

15

HPWR_DIS

High Power Disable

5

34

HPWR_REQ

6

14 & 29

MUTE_GATE_1-

7

30 & 44

MUTE_GATE_2-

Adept Cobra s600/s800 Robot, User’s Guide, Rev L1

Page 107 of 128

This manual is related to the following products: