beautypg.com

Adept s600 Cobra User Manual

Page 45

background image

Chapter 4: System Operation

XIO Input Specifications

Table 4-6. XIO Input Specifications

Operational voltage range

0 to 30 VDC

“Off” state voltage range

0 to 3 VDC

“On” state voltage range

10 to 30 VDC

Typical threshold voltage

V

in

= 8 VDC

Operational current range

0 to 7.5 mA

“Off” state current range

0 to 0.5 mA

“On” state current range

2.5 to 7.5 mA

Typical threshold current

2.0 mA

Impedance (V

in

/I

in

)

3.9 K

minimum

Current at V

in

= +24 VDC

I

in

6 mA

Turn on response time (hardware)

Software scan rate/response time

5 µsec maximum

16 ms scan cycle/
32 ms max response time

Turn off response time (hardware)

Software scan rate/response time

5 µsec maximum

16 ms scan cycle/
32 ms max response time

NOTE: The input current specifications are provided for reference. Voltage sources
are typically used to drive the inputs.

Adept Cobra s600/s800 Robot, User’s Guide, Rev L1

Page 45 of 128

This manual is related to the following products: