Chapter 9: Cleanroom Robots
9.1 Connections
Figure 9-2. Cleanroom Connections
9.2 Requirements
Table 9-2. Cleanroom Robot Requirements
Vacuum
source
0.80 m
3
/min (28 ft
3
/min) minimum volumetric flow rate
6 mm of water (0.2 inches of water) differential pressure measured between
the robot and the vacuum source
3/4 inch NPT female thread pipe fitting at the back of the robot
Compressed
air source
Clean, dry, oil-free compressed air
75 psi (0.52 MPa)
1.4 SCFM (.04 m
3
/min.) flow rate
3/8 inch NPT female thread pipe fitting at the back of the robot, flow regulator
not supplied
Quill inside
diameter
The inside diameter of the quill must be plugged by the user’s end-effector in
order for sufficient vacuum to develop in the outer link.
9.3 Exclusions and Incompatibilities
Table 9-3. Internally Mounted Hand Valves
Installation
considerations
The internal air line normally used to supply the internally-mounted
hand valves (Adept Option Kit P/N 02853-000) is instead used to
provide vacuum to the bellows/outer link. One of the passive 6 mm user
air lines would need to be used instead.
Performance
considerations
The air exhausting from the internally-mounted hand valves (Adept
Option Kit P/N 02853-000) may be of sufficient quantity/ quality to cause
the robot to exceed Class 10 Particulate Limits.
Adept Cobra s600/s800 Robot, User’s Guide, Rev L1