Chapter 9: Cleanroom Robots

9.1 Connections

Figure 9-2. Cleanroom Connections

9.2 Requirements

Table 9-2. Cleanroom Robot Requirements

Vacuum
source

0.80 m

3

/min (28 ft

3

/min) minimum volumetric flow rate

6 mm of water (0.2 inches of water) differential pressure measured between
the robot and the vacuum source

3/4 inch NPT female thread pipe fitting at the back of the robot

Compressed
air source

Clean, dry, oil-free compressed air

75 psi (0.52 MPa)

1.4 SCFM (.04 m

3

/min.) flow rate

3/8 inch NPT female thread pipe fitting at the back of the robot, flow regulator
not supplied

Quill inside
diameter

The inside diameter of the quill must be plugged by the user’s end-effector in
order for sufficient vacuum to develop in the outer link.

9.3 Exclusions and Incompatibilities

Table 9-3. Internally Mounted Hand Valves

Installation
considerations

The internal air line normally used to supply the internally-mounted
hand valves (Adept Option Kit P/N 02853-000) is instead used to
provide vacuum to the bellows/outer link. One of the passive 6 mm user
air lines would need to be used instead.

Performance
considerations

The air exhausting from the internally-mounted hand valves (Adept
Option Kit P/N 02853-000) may be of sufficient quantity/ quality to cause
the robot to exceed Class 10 Particulate Limits.