Chapter 3: Functional Description

3–9

Block Description

February 2013

Altera Corporation

Serial Digital Interface (SDI) MegaCore Function

User Guide

Video Timing Flags Extraction

The TRS match module extracts the F, V, and H video timing flags from the received
data. You can use these flags for receiver format detection, or in the implementation of
a flywheel function.

The TRS match module also identifies the line number and CRC words for HD-SDI.

RP168 Switching Compliance

To meet the RP168 requirements, the transceiver must be able to recover by the end of
the switching line.

Table 3–4

lists the supported video switching type.

f

For more information about the switching line and time for different video formats,
refer to RP168.

Figure 3–5

and

Figure 3–6

show the behaviors of the aligner and format blocks during

the RP168 switching.

The aligner block immediately aligns to the next TRS timing based on the user input
en_sync_switch

signal.

Table 3–4. Supported Video Switching Type

Standard/ Data Rate

Format

RP168 Support

Switching Source

Fixed

Switch (same format)

Yes

HD-1080i30 to HD-1080i30

Fixed

Switch

No

HD-1080 to HD-720

Switch

Fixed

No

HD-1080 to SD-525

Switch

Switch

No

HD-1080 to SD-525

Figure 3–5. Aligner Block Behavior

Notes to

Figure 3–5

:

(1) Mismatch in alignment.

(2) New alignment on the next TRS.

(3) Data aligned to new alignment.

(4) Zero interrupt.

tx_data

dead_time

(1)

switch

line

10200

10200

00000H

00000H

40020H

10200H

10200H

10200H

10200H

10200H

10200H

10200H

10200H

10200H

10

11

12

12H

03H

alignment

align_locked/rx_status[2]

rx_data

(2)

(2)

(4)

(3)