beautypg.com

Log splitter control valve removal – Cub Cadet I-Beam Style User Manual

Page 271

background image

6-72

Control Valve

1. Loosen the hose clamp securing the return

hose to the control valve return elbow using a
5/16" socket or a flat-blade screw driver. See
Figure 6-121.

2. Remove, drain, cap and position the return

hose out of the work area.

3. Remove, drain, cap and position the high pres-

sure hydraulic hose out of the work area using

channel locks and a 1-1/16" wrench. See Fig-
ure 6-122.

4.

Remove the steel hydraulic tube that connects
from the rear port of the hydraulic cylinder to
the 90 degree fitting on the control valve using
two 7/8" wrenches. See Figures 6-123 and 6-
124.

Log Splitter Control Valve Removal

Figure 6-120.

Figure 6-121.

Figure 6-122.

Figure 6-123.

Log Splitters 2.fm Page 72 Wednesday, February 20, 2002 1:35 PM