CANOGA PERKINS CanogaOS Configuration Guide User Manual

Page 87

background image

CanogaOS Configuration Guide

Proprietary & Confidential Canoga Perkins Metro Ethernet Switches

Page 87 of 350

DUT (config-if)#exit

Exit the Interface mode

DUT (config)#ethernet cfm enable

Enable CFM globally.

DUT (config)#ethernet cfm cc level 5 vlan 30 interval 10000

Configure the interval in the selected
service instance (MA) instance with
the configured domain-level.

DUT (config)#ethernet cfm cc enable level 5 vlan 30

Enable continuity check in the
selected service instance (MA)
instance with the configured
domain-level.

DUT(config-if)# end

Exit the Interface mode.


Bridge2

DUT# configure terminal

Enter the Configure mode.

DUT(config)#

vlan database

Enter the VLAN database..

DUT(config vlan)# vlan 30

Configure VLAN 30

DUT(config vlan)# exit

Exit the VLAN database

DUT(config)# ethernet cfm domain customer level 5

Create a domain,

DUT (config-ether-cfm)#service cst vlan 30

Define a Maintenance Association
(MA) for the domain created.

DUT (config-ether-cfm)#exit

Exit the CFM database.

DUT(config)# ethernet cfm domain provider level 3

Create a domain

DUT (config-ether-cfm)#service cst vlan 30

Define a Maintenance Association
(MA) for the domain created.

DUT (config-ether-cfm)#exit

Exit the CFM database.

DUT(config)#interface eth-0-9

Specify the interface (eth-0-9)to be
configured and enter the Interface
mode

DUT(config-if)# switchport mode trunk

Set the switching characteristics of
this interface to trunk mode.

DUT(config-if)# switchport trunk allowed vlan all

Enable all VLAN IDs on this port.

DUT (config-if)# ethernet cfm mip level 5

Configure a maintenance
Intermediate point (MIP).

DUT (config-if)#ethernet cfm mep level 3 up mpid 666 vlan 30

Configure a maintenance end point
(MEP).

DUT (config-if)# no shutdown

Bring up the interface.