CANOGA PERKINS CanogaOS Configuration Guide User Manual
Page 345

CanogaOS Configuration Guide
Proprietary & Confidential Canoga Perkins Metro Ethernet Switches
Page 345 of 350
DUT#configure terminal
Enter global configuration mode.
DUT#show running-config
Verify your entries.
SNMPv3 notifications:
DUT#configure terminal
Enter global configuration mode.
DUT(config)#snmp-server trap enable all
Enable all supported traps.
DUT(config)#snmp-server notify notif1 tag tmptag trap
Configure a trap notify item for SNMPv3.
DUT(config)#snmp-server target-address targ1 param
parm1 10.0.0.2 taglist tmptag
Configure a remote trap manager’s IP address.
DUT(config)#snmp-server target-params parm1 user usr1
security-model v3 message-processing v3 noauth
Add a local user to SNMPv3 notifications.
DUT(config)#end
Return to privileged EXEC mode.
DUT#show running-config
Verify your entries.
47.1.5 Displaying SNMP Status
To display SNMP input and output statistics, use the show snmp-server privileged EXEC
command.
DUT#show snmp-server community
Displaying SNMP communities.
DUT#show snmp-server group
Displaying SNMP groups.
DUT#show snmp-server access
Displaying SNMP accesses.
DUT#show snmp-server view
Displaying SNMP views.
DUT#show snmp-server trap-receiver
Displaying SNMPv1 and SNMPv2c notifications’ remote
receivers.
DUT#show snmp-server notify
Displaying notifies for SNMPv3 notifications,
DUT#show snmp-server target-address
Displaying IP address of SNMPv3 notifications’ receivers.
DUT#show snmp-server target-params
Displaying other parameters for SNMPv3 notifications.