Banner SC22-3E Safety Controller with Ethernet User Manual
Page 70
Map Outputs—This option is used to select which of the Safety Output(s) the input controls. Any combination of 1, 2, or all 3 outputs
may be selected, but at least one must be selected. All safety devices, plus reset and ON/OFF non-safety devices must be mapped to
one or more Safety Outputs. Map mute enable devices, mute sensors, and bypass sensors to a safety input device.
1. Select Map Outputs in the Input Properties menu, and press OK.
2. To map the input to an output, use the up/down arrows to select the output, then press
OK.
3. A filled-in circle on the display indicates the input is mapped to the corresponding output;
an empty circle indicates the input is not mapped to that output.
4. To add or remove the input mapping, select the output and press OK. When the input is
mapped to the Safety Outputs as desired, select Save and press OK.
5. After the input is mapped to the Safety Outputs, the display returns to the Input Proper-
ties menu.
The screen shows device ES01 mapped to all three Safety Outputs.
Select Reset Logic—To select automatic or manual reset logic, select Reset Logic and press OK.
1. Use the left/right arrows to select the desired reset logic parameter and press OK.
2. The display returns to the Input Properties menu.
Save the Input Device Parameters—When all of the device’s parameters have been set as
desired, select < Done > and press OK to save the parameters.
1. The display indicates the input parameters were saved. Press OK to continue.
2. The display returns to the Edit Inputs menu.
SC22-3/-3E Safety Controller Instruction Manual
70
www.bannerengineering.com - tel: 763-544-3164
P/N 133487 rev. C