3 configure input device properties – Banner SC22-3E Safety Controller with Ethernet User Manual
Page 69
• Cancel OFF-delay switch
Select an Input Device (Either Safety or Non-Safety)—Use the left/right arrows to select
the proper device, then press OK. The arrows at the top of the screen indicate whether more
options are available to the left or to the right. After the device is selected, a new screen ap-
pears with the appropriate properties to select for that device.
6.5.3 Configure Input Device Properties
For each input device, the following parameters must be configured:
• Name (or use the auto-generated default name)
• Circuit type
• Terminal assignments (or use the auto-generated terminal assignments)
• Reset logic (for some devices)
• Output mapping or input mapping (depending on device)
Enter Input Device Name—The Enter Name menu is displayed. A default name automatically appears, but the device may be renamed
(up to 10 characters).
1. Use the left/right arrows to select the character position.
2. Use the up/down arrows to select the character for each position (choices A-Z, 0-9, -,
+, or space).
3. When the screen (as shown below) shows the correct device name, press OK.
Input Properties Menu—The Input Properties menu is used to:
• Select the input device’s circuit type
• Edit the terminal assignments, if needed
• Select the output(s) (or input), the input will control
• Select between automatic and manual reset logic (depending on device)
Select the Circuit Type of the Input—Use the up/down arrows to select Select Circuit Type, and press OK.
See section
10 Input Device and Safety Category Reference
on page 90 for more information about safety circuit integrity
levels and the capabilities of each circuit type.
1. The Select Circuit Type menu appears.
2. Use the left/right arrows to select the desired circuit type (a dual-channel, 4-terminal cir-
cuit type is shown below) for the input device and press OK.
3. After the circuit type is selected, the display returns to the Input Properties menu.
Edit the Terminal Assignments—When the input circuit type is selected, the Safety Controller automatically assigns the next available
terminals for the input device. Only unassigned terminals can be assigned. (Exception: Terminals used for a specific input device can be
assigned twice during the edit process, if the same terminals will be used, in a different order, for this specific device.) To view and
change these terminal assignments, select Edit Terminals, and press OK.
1. Use the left/right arrow buttons to select the terminal assignment to be changed.
2. Use the up/down arrows to change the terminal assignment.
3. When the terminal assignments are as desired, press OK.
4. After the terminal assignments are approved, the display returns to the Input Properties
menu.
SC22-3/-3E Safety Controller Instruction Manual
P/N 133487 rev. C
www.bannerengineering.com - tel: 763-544-3164
69