beautypg.com

Banner RP-QM90 Rope Pull Switch User Manual

Rp-qm90 series rope pull switches, Datasheet, Important... read this first

background image

Datasheet

Positive-opening safety contacts (IEC 60947-5-1), not dependent

upon springs

Contacts latch open when rope is pulled; requires manual reset

Heavy-duty die cast metal housing, rated IP65, suitable for demanding

industrial environments

Rope spans up to 100 m (330 ft), with the switch mounted in the center

of the span

Both safety contacts are closed with normal rope tension, and open when

rope is pulled or if rope breaks (or if tension is reduced from normal

amount)

Extra contacts for monitoring or to provide dual-channel input to a safety

module

Switch actuator position clearly indicates when rope has proper tension

for operation

Long life, switch rated at 1 million mechanical operations, minimum

Protective Earth Terminal (IEC 60947-1)

Model

Max. Overall

Rope Length

Run Position

Cable Pulled

(either side)

Cable Break

(either side)

Switching Diagram

RP-QM90F-100L

100 m (330 ft)

23

24

11

12

11

12

23

24

23

24

11

12

11

12

23

24

23

24

11

12

11

12

23

24

11 - 12

23 - 24

40°

40°

30°

30°

0

Lock

70N

70N

Lock

Lever

11 - 12

23 - 24

Right

Left

Contacts:

Open

Closed

NOTE: This symbol

for a positive-opening safety contact (IEC 60947-5-1) is used in the switching

diagram to identify the point in actuator travel where the normally-closed safety contact is fully open.

Important... Read This First

Regarding the Use of Rope Pull Switches. In the United States, the functions that Banner rope pull switches are

intended to perform are regulated by the Occupational Safety and Health Administration (OSHA). Whether or not any

particular rope pull switch installation meets all applicable OSHA requirements depends upon factors that are beyond the

control of Banner Engineering Corp. These factors include the details of how the switches are applied, installed, wired,

operated, and maintained.

Banner Engineering Corp. has attempted to provide complete application, installation, operation, and maintenance

instructions in this document. Direct any questions regarding the use or installation of rope pull switches to the factory

applications department.

RP-QM90 Series Rope Pull Switches

P/N 62086 Rev. D

4 February 2014

62086