Banner ES-FA-6G Safety Module User Manual
Es-ua-5a and es-va-5a e-stop safety modules, Important: read this first
Model ES-UA-5A for 12-24V dc/115 ac operation; model ES-VA-5A for 12-24V dc/230 ac operation
Original Instructions
• Monitors emergency stop devices, such as palm buttons and rope/cable
pulls, and positive-opening safety switches used for guard/gate inter-
locking
• The safety inputs can monitor:
• Hard/relay contacts in a dual-channel hookup using terminals S11-
S12 and S21-S22, or
• A +24V dc source switched by hard/relay contacts in single-channel
hookup
• Four normally open output switching channels for connection to control-
reliable power interrupt circuits and three auxiliary output channels
• Automatic reset or monitored manual reset
• Design complies with standards ANSI B11.19, UL991, ISO 13850
(EN418), and ISO 13849-1 (EN954-1) (Safety Category 4)
• For use in functional stop category 0 applications per ANSI NFPA 79
and IEC/EN60204-1
• 6 amp safety output contacts; 5 amp aux. output contacts
• Plug-in terminal blocks
Models
Supply Voltage
Outputs
Output Rating
ES-UA-5A
12-24V dc or 115V ac
4 Normally open safety
1 Normally closed aux.
2 Solid-state aux.
N.O. Safety Outputs: 6 A
N.C. Aux. Outputs: 5 A
SS Aux. Outputs: 100 mA
ES-VA-5A
12-24V dc or 230V ac
WARNING: Not a Stand-Alone Safeguarding Device
This Banner device is not a stand-alone point-of-operation guarding device, as defined by OSHA
regulations. It is necessary to install point-of-operation guarding devices, such as safety light screens
and/or hard guards, to protect personnel from hazardous machinery. Failure to install point-of-operation
guards on hazardous machinery can result in a dangerous condition which could lead to serious
injury or death.
Important: Read This First
The user is responsible for satisfying all local, state, and national laws, rules, codes, and regulations relating to the use of this
product and its application. Banner Engineering Corp. has made every effort to provide complete application, installation, operation, and
maintenance instructions. Please direct any questions regarding the use or installation of this product to the factory applications depart-
ment at the telephone numbers or address found at
.
The user is responsible for making sure that all machine operators, maintenance personnel, electricians, and supervisors are thorough-
ly familiar with and understand all instructions regarding the installation, maintenance, and use of this product, and with the machinery it
controls. The user and any personnel involved with the installation and use of this product must be thoroughly familiar with all applicable
standards, some of which are listed within the specifications. Banner Engineering Corp. makes no claim regarding a specific recommen-
dation of any organization, the accuracy or effectiveness of any information provided, or the appropriateness of the provided information
for a specific application.
Applicable U.S. Standards
ANSI B11 Standards for Machine Tools Safety
ES-UA-5A and ES-VA-5A E-Stop Safety Modules
P/N 122365 Rev. E
4/19/2013
0 122365
1