3.3 Ethernet Cordsets

Shielded Models

Cat5e Crossover Models

Length

STP07

STPX07

2.1 m

STP25

STPX25

7.6 m

STP50

STPX50

15.5 m

STP75

STPX75

23 m

3.4 Interface Modules

SC-IM9 series interface modules are for use only with the Safety Controller; dry contacts for use with higher ac/dc voltage and current.
With 10A output, DIN-mount housing, removable (plug-in) terminal blocks for OSSD outputs (screw terminal block supplied). Measures
approx. 72 mm H, 170 mm D, and 45 mm , 90 mm, or 140 mm W, (2.8" H, 6.7" D, and 1.8", 3.5", or 5.5" W) depending on model. See
datasheet p/n 131845 for more information.

NOTE:

External device monitoring (EDM) is required to be wired separately to the N.C. contacts to comply with ISO 13849-1

categories and ANSI/OSHA control reliability; see section

4.7.1 External Device Monitoring (EDM)

on page 40.

Model

Description

Supply

Voltage

Inputs (Safety

Controller Outputs)

Safety Outputs

Output

Rating

EDM Con-

tacts

SC-IM9A

For use with 1 Safety
Controller Safety Output

24V dc

(Controller

supplied)

2

(SO1)

3 N.O.

10 amps

1 N.C. pair per

output

SC-IM9B

For use with 2 Safety
Controller Safety Outputs

4

(SO1 and SO2)

Total of 6

(3 N.O. per output)

SC-IM9C

For use with 3 Safety
Controller Safety Outputs

6

(SO1, SO2, and SO3)

Total of 9

(3 N.O. per output)

IM-T-9 series interface modules have 6A output, 22.5 mm DIN-mount housing, removable (plug-in) terminal blocks. Low current rating of
1V ac/dc @ 5 mA, high current rating of 250V ac/dc @ 6A. See datasheet p/n 62822 for more information.

NOTE:

External device monitoring (EDM) is required to be wired separately to the N.C. contacts to comply with ISO 13849-1

categories and ANSI/OSHA control reliability; see section

4.7.1 External Device Monitoring (EDM)

on page 40.

Model

Supply Voltage

Inputs

Safety Outputs

Output Rating

EDM Contacts

Aux. Outputs

IM-T-9A

24V dc

2 (dual-channel

hookup)

3 N.O.

6 amps

2 N.C.

IM-T-11A

2 N.O.

1 N.C.

3.4.1 Mechanically Linked Contactors

Provides an additional 10 or 16 amp carrying capability to any safety system. If used, two contactors per Safety Output pair (e.g., 2 x
SO1), are required. The N.C. contacts are to be used in an external device monitoring (EDM) circuit.

NOTE:

External device monitoring (EDM) is required to be wired separately to the N.C. contacts to comply with ISO 13849-1

categories and ANSI/OSHA control reliability; see section

4.7.1 External Device Monitoring (EDM)

on page 40.

SC22-3/-3E Safety Controller Instruction Manual

22

www.bannerengineering.com - tel: 763-544-3164

P/N 133487 rev. C