3 ethernet cordsets, 4 interface modules, 1 mechanically linked contactors – Banner SC22-3E Safety Controller with Ethernet User Manual
Page 22
3.3 Ethernet Cordsets
Shielded Models
Cat5e Crossover Models
Length
STP07
STPX07
2.1 m
STP25
STPX25
7.6 m
STP50
STPX50
15.5 m
STP75
STPX75
23 m
3.4 Interface Modules
SC-IM9 series interface modules are for use only with the Safety Controller; dry contacts for use with higher ac/dc voltage and current.
With 10A output, DIN-mount housing, removable (plug-in) terminal blocks for OSSD outputs (screw terminal block supplied). Measures
approx. 72 mm H, 170 mm D, and 45 mm , 90 mm, or 140 mm W, (2.8" H, 6.7" D, and 1.8", 3.5", or 5.5" W) depending on model. See
datasheet p/n 131845 for more information.
NOTE:
External device monitoring (EDM) is required to be wired separately to the N.C. contacts to comply with ISO 13849-1
categories and ANSI/OSHA control reliability; see section
4.7.1 External Device Monitoring (EDM)
on page 40.
Model
Description
Supply
Voltage
Inputs (Safety
Controller Outputs)
Safety Outputs
Output
Rating
EDM Con-
tacts
SC-IM9A
For use with 1 Safety
Controller Safety Output
24V dc
(Controller
supplied)
2
(SO1)
3 N.O.
10 amps
1 N.C. pair per
output
SC-IM9B
For use with 2 Safety
Controller Safety Outputs
4
(SO1 and SO2)
Total of 6
(3 N.O. per output)
SC-IM9C
For use with 3 Safety
Controller Safety Outputs
6
(SO1, SO2, and SO3)
Total of 9
(3 N.O. per output)
IM-T-9 series interface modules have 6A output, 22.5 mm DIN-mount housing, removable (plug-in) terminal blocks. Low current rating of
1V ac/dc @ 5 mA, high current rating of 250V ac/dc @ 6A. See datasheet p/n 62822 for more information.
NOTE:
External device monitoring (EDM) is required to be wired separately to the N.C. contacts to comply with ISO 13849-1
categories and ANSI/OSHA control reliability; see section
4.7.1 External Device Monitoring (EDM)
on page 40.
Model
Supply Voltage
Inputs
Safety Outputs
Output Rating
EDM Contacts
Aux. Outputs
IM-T-9A
24V dc
2 (dual-channel
hookup)
3 N.O.
6 amps
2 N.C.
—
IM-T-11A
2 N.O.
1 N.C.
3.4.1 Mechanically Linked Contactors
Provides an additional 10 or 16 amp carrying capability to any safety system. If used, two contactors per Safety Output pair (e.g., 2 x
SO1), are required. The N.C. contacts are to be used in an external device monitoring (EDM) circuit.
NOTE:
External device monitoring (EDM) is required to be wired separately to the N.C. contacts to comply with ISO 13849-1
categories and ANSI/OSHA control reliability; see section
4.7.1 External Device Monitoring (EDM)
on page 40.
SC22-3/-3E Safety Controller Instruction Manual
22
www.bannerengineering.com - tel: 763-544-3164
P/N 133487 rev. C