App a - specifications, General specifications, Appendix a – Rockwell Automation 2094-EN02D-M01-S1 Kinetix 6200 and Kinetix 6500 Safe Speed Monitoring Safety Reference Manual User Manual
Page 143: Specifications, Appendix
Rockwell Automation Publication 2094-RM001C-EN-P - May 2013
143
Appendix
A
Specifications
This appendix provides product specifications for the safe speed monitoring
safety functions.
General Specifications
These specifications apply to the safe speed monitoring safety functions.
Table 39 - Safety Specifications
Topic
Page
Attribute
Value
Standards
IEC/EN60204-1, ISO12100, IEC 61508, IEC 61800-5-2
Safety category
Cat. 4 and PLe per EN ISO 13849-1;
SIL CL3 per IEC 61508 and EN 62061
Power supply (user I/O)
21.6…28.8V DC (24V nom), 0.9…1.2 x rated voltage
(1)
PELV or SELV
1.35 A, max
(1) 2.0 A fast-acting fuse required.
Power consumption
36 W
SLS outputs
24V DC, 20 mA, short-circuit protected
SS outputs
24V DC, 20 mA, short-circuit protected
(2)
(2) Maximum test pulse width equals 700 μs, depending on application specific output load.
Door control outputs
24V DC, short-circuit protected
• 0.75 A, bipolar (Power to Release/Power to Lock) configuration
• 20 mA, cascading (2Ch Source) configuration
Pulse outputs
24V DC, 30 mA, short-circuit protected
Safety inputs SS_In, SLS_In,
ESM_In, DM_In, LM_In
5 mA per input, max
Input ON Voltage, min
16.5V
Input OFF Voltage, max
5V
Input OFF Current, max
2 mA
Input-to-output response time
20 ms
Overspeed Response Time
User-configurable
Reset_In Input
5 mA per input, max
Reset time, max
(3)
(3) When multiple drives are cascaded together, the safety reaction time for the last drive is the total of all drives times, 400 ms.
400 ms per axis