Configure the rn10c devicenet scanner – Rockwell Automation 1752-L24BBBE SmartGuard 600 Controllers User Manual User Manual
Page 115

Rockwell Automation Publication 1752-UM001E-EN-P - June 2014
115
Configure Your Controller for DeviceNet Communication
Chapter 7
Configure the RN10C DeviceNet Scanner
Follow this procedure to configure the RN10C DeviceNet scanner.
The shortcut in RSLinx Enterprise software should appear similar as shown.
Note that the slot number of the RN10C is 2.
1.
Right-click the RN10C scanner and choose Properties.
The following dialog box appears.
2.
Enter the name of the scanner.
3.
From the appropriate pull-down menu, choose the Node Address, Slot in
the Virtual Backplane, and Baud rate.
The PanelView Plus interface is configured for DeviceNet node 7. The
SmartGuard controller has the DIP switches set for auto-sensing (left/
left/left/right from top to bottom). Choose the the baud rate that is
appropriate for your application.
4.
Click the I/O Configuration tab.