2 short overview of the functions, 3 commissioning, Commissioning – Lenze PLC Designer V2.x User Manual
Page 62: Plc designer v2.x| lenze application samples
PLC Designer V2.x| Lenze Application Samples
Working with the sample projects
8400 HighLine - "LAS_40_INTF_Can_84HL_TabPos" sample project
62
L
1.3 EN - 07/2012
8.2.2
Short overview of the functions
8.2.3
Commissioning
1. Wire the power connections
– Use the mounting instructions supplied with the controller to correctly use the
power connections according to the requirements of your device.
2. Wire the control terminals
3. Connect USB diagnostic adapter.
4. Switch on the voltage supply of the controller.
– Connect mains voltage.
When the green LED "DRV-RDY" is blinking and the red LED "DRV-ERR" is off, the controller
is ready to start and you can continue with the commissioning.
Mode
Description
Automatic
In the automatic mode a sequence runs over an infinite loop.
Selection:
When the drive is referenced...
1.Travel to Position 1,
2.Travel to Position 2,
3.Start at (1.) again.
Manual
In manual mode, the controller can be actuated by setting the individual
control bits manually (Jog1, Jog2, QSP, ErrorReset...). Like this, the controller
can be actuated in manual mode, for instance for cleaning or changing the
tools.
Service
The service mode serves to adjust the controller.
Selection:
• Travel in positive direction for one second,
• Stop for one second,
• Travel in negative direction for one second.
Homing
In the homing mode the drive is referenced.
• Either the home position is set directly, or a homing is started.
Read the mounting instructions supplied with the controller first before you start
working!