The L_S84_Drive8400.lib library
L_S84_TablePositioningHL - profile data record management
11.6.2
Structure of S84_DriveStatus_8400HL_TablePositioning - status of the controller
Identifier/data type
Control bits in the controller
Bit
Identifier
Meaning
xDriveError
BOOL
0
bDriveFail
Controller is in error status (TRUE: Error
active)
xStateBit1
BOOL
1
bGPSignalOut1
Binary signal monitor: Output signals
xStateBit2
BOOL
2
bGPSignalOut2
xDriveEnabled
BOOL
3
bCInhActive
Controller inhibit is active
xDriveReady
BOOL
4
bDriveReady
Status signal "Controller is ready for
operation"
xDigin5
BOOL
5
DigitalInput.bIn5
Signal of digital input DI5 ... DI7
xDigin6
BOOL
6
DigitalInput.bIn6
xDigin7
BOOL
7
DigitalInput.bIn7
xPosInTarget
BOOL
8
bInTarget
Target position (actual value) is in the target
window
xPosBusy
BOOL
9
bProfileBusy
Profile positioning is active
xHomePosAvailable
BOOL
10
bHomePosAvailable
Home position is known
xSpeedEqZero
11
bSpeedActCompare
Result of the speed comparison
xDigin3_LimitSwPositive
13
DigitalInput.bIn3
Digital input 3
xDigin4_LimitSwNegative
12
DigitalInput.bIn4
Digital input 4
xQSPActive
BOOL
14
bQSPIsActive
Quick stop is active
xStateBit15
BOOL
15
Not assigned
Not assigned
rActualSpeed
REAL
nMotorSpeedAct_a
Actual speed value
xCommunicationOK
BOOL
L_SCB_GetNodeDataRxPDO1 - read out data ( 285)
L_SCB_GetNodeDataRxPDO2 - read out data ( 286)
xOptional
BOOL
L_SCB_GetStateOptional - check with regard to "OptionalDevice" ( 287)
eCanNodeState
SCB_StateCanNode
rActualPosition
REAL
Current position