15 l_ssc_setaxisdata - machine parameters, Plc designer v2.x| lenze application samples – Lenze PLC Designer V2.x User Manual
Page 326
PLC Designer V2.x| Lenze Application Samples
The L_SSC_Scaling.lib library
L_SSC_SetAxisData - machine parameters
326
L
1.3 EN - 07/2012
20.15
L_SSC_SetAxisData - machine parameters
With this FB the machine parameters of a higher-level drive can be mapped. The FB
conditions the machine parameters, which you specify in the physical units of the machine
via parameters, for the internal representation.
At the output scAxisData the FB provides a pointer to the data structure with the
machine parameters conditioned.
In order to pass the machine parameters to another FB which requires these data for
internal calculations, the output scAxisData is to be connected to the input with the
same name of the corresponding FB.
Inputs
Identifier/data type
Information/possible settings
rFeedConstant
REAL
Feed constant
• Initialisation: 360.0 units
rCycleLength
REAL
Cycle
• Initialisation: 360.0 units
dwGearNumerator
DWORD
Gearbox factor numerator
• Initialisation: 1
dwGearDenominator
DWORD
Gearbox factor denominator
• Initialisation: 1
rMaxSpeed
REAL
Reference speed
sAxisName
STRING(16)
Axis name
eMode
SSC_Mode :=
MODULO
Traversing range
• 0 unlimited
• 1 limited
• 2 modulo (Lenze setting)
dwResolution
DINT
Resolution of one revolution