3 manual mode ("manual jog"), Manual mode ("manual jog"), Plc designer v2.x| lenze application samples – Lenze PLC Designer V2.x User Manual
Page 50
PLC Designer V2.x| Lenze Application Samples
Working with the sample projects
8400 StateLine - "LAS_40_INTF_Can_84SL_Speed" sample project
50
L
1.3 EN - 07/2012
8.1.4.3
Manual mode ("Manual jog")
The 8400 StateLine can be controlled by means of the visualisation of block
L_S84ActuatorSpeedSL in manual operation. Via the visualisation of block
L_S84ReadErrorCode the current error can be read out.
Button selects the manual (manual jog) mode.
In the control and status panel the FB for controlling the 8400 Stateline is visualised.
Note: Enable the controller via FB input xEnable to activate the manual mode.
Afterwards the controller can be operated via the visualisation in manual operation.
The xQsp button must be activated to activate quick stop.
Further information on the FB can be found in the following section:
L_S84_ActuatorSpeedSL - actuation of the 8400 StateLine controller
Area visualises the FB for reading out the errors from the controller.
Further information on the FB can be found in the following section:
L_S84_ReadErrorCode - read out error status
Select mode
Reading out an
error
Control/status panel