1 actuation to the controller, Plc designer v2.x| lenze application samples – Lenze PLC Designer V2.x User Manual
Page 268
PLC Designer V2.x| Lenze Application Samples
The L_S8V_Drive82Vector.lib library
L_S8V_ActuatorSpeed - actuation of the 8200 vector controller
268
L
1.3 EN - 07/2012
14.1.1
Actuation to the controller
The Lenze sample projects offer you a predefined mapping for the controller, in order to be
able to commission and control it. To what extent the assignments of the FB in the »PLC
Designer« are associated to the control bits in the respective device can be gathered from
the following table overview.
Further information on the controller can be found in the following
documentation:
• System manual (SHB) 8200 vector - Global Drive
– Section Function library
Code table | Controller control word (parameter
channel)
Identifier/data type
Control bits in the controller
Bit
Identifier
Meaning
xJog1
BOOL
0
NSET1-JOG1
Setpoint selection 1
xJog2
BOOL
1
NSET1-JOG2
Setpoint selection 2
xCcw
BOOL
2
DCTRL1-CW/CCW
Activate CCW rotation
xQSP
BOOL
3
DCTRL1-QSP
Activate quick stop
xNSet_RfgStop
REAL
4
NSET1-RFG1-STOP
Stop ramp function generator
xNSet_Rfg0
5
NSET1-RFG1-0
Ramp function generator input = 0
• RFG1 = ramp function generator of main
setpoint
xMPOT_UP
6
MPOT1-UP
UP function of motor potentiometer
xMPOT_DOWN
7
MPOT1-DOWN
DOWN function of motor potentiometer
xFreeBit08
BOOL
8
Reserved
xEnable
BOOL
9
DCTRL1-CINH
1 = Enable controller (RFR)
xErrorSet
BOOL
10
DCTRL1-TRIP-SET
1 = set error (TRIP set)
xErrorReset
BOOL
11
DCTRL1-TRIP-RESET
1 = reset error (TRIP reset)
xFreeBit12
BOOL
12
Not assigned
xFreeBit13
BOOL
13
Not assigned
xFreeBit14
BOOL
14
Not assigned
xFreeBit15
BOOL
15
Not assigned
rNSet
REAL
Speed setpoint