Plc designer v2.x| lenze application samples – Lenze PLC Designer V2.x User Manual
Page 265
1.3 EN - 07/2012
L
265
PLC Designer V2.x| Lenze Application Samples
The L_SCS_DriveECS.lib library
L_SCS_SupplyModule - actuation of the ECS servo system power supply module
13.4.2
Structure of SCS_Status_Supply - status of the controller
Further information on the internal interfaces of the controller can be found in
the Operating instructions (BA) ECSxE_power supply module:
• Section Configuration
Configure system bus | Assignment of the status words
Identifier/data type
Control bits in the
controller
Bit
Identifier
Meaning
xBTB_ReadyForOperation
BOOL
0
STA1_BTB
TRUE: Power supply module ready
xWarning
BOOL
1
STA1_
WARNING
TRUE: Warning active
xMessage
BOOL
2
STA1_MESSAGE
TRUE: Message active
xTrip
BOOL
3
STA1_TRIP
Status message
TRUE: Error message active
xKSB_FAIL
BOOL
4
STA1_KSB_FAIL
TRUE: No short-circuit braking possible,
since the DC bus is loaded externally.
xKSB_Active
BOOL
5
STA1_KSB_ACTIV
E
1 = Pulse inhibit (DCTRL-IMP) active,
inverter inhibited
xK1_Active
BOOL
6
STA1_K1_ON
TRUE: No short-circuit braking possible,
since the DC bus is loaded externally.
xK2_Active
BOOL
7
STA1_K2_ON
TRUE: Short-circuit braking active
xDI1
BOOL
11
STA1_DI1
1 = The actual position is in the target
window (C3034) around the target
position
(message: Target position reached)
xDI2
BOOL
12
STA1_DI2
1 = The dwell time (C3035) has expired.
Note: Bit is reset to "0" when positioning
is started.
xToggleBit
BOOL
13
STA1_TOGGLE
Toggle bit
xFreeBit14
BOOL
14
free
Not assigned
xFreeBit15
BOOL
15
free
Not assigned
eErrorCode
SCS_ErrorCode
Reset error