2 short overview of the functions, 1 commissioning, Commissioning – Lenze PLC Designer V2.x User Manual
Page 168: Plc designer v2.x| lenze application samples
PLC Designer V2.x| Lenze Application Samples
Working with the sample projects
9300 servo - "LAS_40_INTF_Can_93_Speed" sample project
168
L
1.3 EN - 07/2012
8.7.2
Short overview of the functions
8.7.2.1
Commissioning
How to commission the 9300:
1. Connect the 9300 servo inverter and the Engineering PC to the PC system bus
adapter (EMF2177).
2. Switch on voltage supply.
Mode
Description
Automatic
In the automatic mode a sequence runs over an infinite loop.
Selection:
• Travel for three seconds at speed1,
• then for five seconds at speed2,
• Start with speed1 again
Manual
In manual mode, the controller can be actuated by setting the individual
control bits manually (Jog1, Jog2, QSP, ErrorReset...). Like this, the controller
can be actuated in manual mode, for instance for cleaning or changing the
tools.
Service
The service mode serves to adjust the controller.
Selection:
• Travel in positive direction for one second,
• Stop for one second,
• Travel in negative direction for one second.
Read the mounting instructions supplied with the controller first before you start
working!