11 the l_s84_drive8400.lib library, The l_s84_drive8400.lib library, Plc designer v2.x| lenze application samples – Lenze PLC Designer V2.x User Manual
Page 235
1.3 EN - 07/2012
L
235
PLC Designer V2.x| Lenze Application Samples
The L_S84_Drive8400.lib library
L_S84_ActuatorSpeedBL - actuation of the 8400 BaseLine controller
11
The L_S84_Drive8400.lib library
This chapter describes the function blocks of the L_S84_Drive8400 function library. The
function blocks of this function library serve to parameterise the Lenze L-force Inverter
Drive 8400.
11.1
L_S84_ActuatorSpeedBL - actuation of the 8400 BaseLine controller
This FB serves to actuate the 8400 BaseLine.
Inputs
Outputs
Further information on the controller can be found in the following
documentation:
• Software manual (SW) 8400 StateLine frequency inverter
• Software manual (SW) 8400 HighLine frequency inverter
Identifier/data type
Information/possible settings
scDriveControl
S84_DriveControl_8400BL
Structural data for drive control
xOptional
BOOL
Optional setting for the CAN node
FALSE Normal operation (transmission and reception via PDO)
TRUE The CAN node is set to the "Optional" mode to be able to receive
PDOs.
byNodeNumber
BYTE
Node number
byMasterNumber
BYTE
Interface number (0...3)
Identifier/data type
Information/possible settings
scDriveStatus
S84_DriveStatus_8400BL
Structural data regarding the drive status
xInternalControlActive
BOOL
TRUE: Internal control active