Event reporter, Report on active notification – 2N NetStar Admin manual User Manual
Page 97

97
Event Reporter
Find the Event reporter in the
Network – Supervision Services – Event Reporter
menu. Here you can set the basic rules for sending info SMS on system parts. This
function is subject to licence!
Event– use this parameter to set the event type to be SMS–reported. Choose
one of the following options:
PBX restart – PBX restart notification.
PBX keepalive – sending of keepalive messages for PBX checking
purposes. Set the keepalive sending period in the Planned events in the
menu
Global data
.
Port ready – notification of a virtual port function reactivation.
Port busy – notification of a virtual port occupation. The BRI and PRI ports
are considered busy whenever all channels have been occupied. This
function cannot be used for the SIP or SMTP port.
Port error – virtual port error notification.
Storage full – notification of a functionless logical storage due to
overfilling.
No call port credit – notification of low credit for a defined virtual port.
No call SIM credit – notification of low credit for a defined SIM card.
No call terminal credit – not implemented yet.
No call user credit – notification of low credit for a defined user.
No SMS port credit – notification of SMS limit exhaustion for a defined
port.
No SMS SIM credit – notification of SMS limit exhaustion for a defined
SIM card.
No SMS terminal credit – not implemented yet.
No SMS user credit – notification of low credit for a defined user.
State of status control object Error – notification of passing of the
selected status control object into the Error state.
State of status control object OK – notification of passing of the
selected status control object into the OK state.
Do not report more often than [s] – here set the report sending hysteresis to avoid
excessive report sending due to repeated port changes. The states to which a
hysteresis timeout applies are reported at once (within one report) after the timeout.
Report on active notification
The block sets how an active event shall be reported.
Message – specification of the text of the SMS to be sent whenever the selected
event happens (Port error, Storage full, etc.), i.e. becomes active. If the
Message field is left blank, no SMS will be sent. In addition to standard texts,
the following dynamic strings may be entered.
%n - name - here enter the name of the event reporter that recorded the
event.
%d - date - here enter the PBX date and time valid at the instant of event
recording.
%k - key - here enter the name of the port to which the event relates.
%v - value - here enter the event value. At present, there is no event to
meet this parameter