Figure: View of PBX Property Settings

Connection properties

The dialogue shown in figure below helps you create a PBX connection or change the
properties of an existing PBX connection. The parameter meanings are as follows:

Connection name – here enter the name of the selected connection.
Modes  –  use  this  parameter  to  define  whether  the  connection  will  support  the
on-line, off-line or both modes.
Download trace – use this option to disable or restrict trace downloading from
the PBX. Particularly useful for modem connections. *Any of the following modes
can be selected:

Only new  –  Only  the  new  trace  is  sent  to  the  tool  existent  since  the
moment of PBX connection.
Never  –  No  trace  is  sent  to  the  tool  (useful  for  trouble  making  modem
connections).
Always – Approximately a 300kB – 1MB trace is read out of the PBX buffer
upon connection and sent to the tool. Useful for sending the trace after the
PBX start up.

Connection type – use this option to define the PBX connection type. Typically,
the TCP/IP or modem connection is selected. Use the TCP/IP, enter the PBX CPU
IP address and the port to be used (6992 by default). With a modem choose the
one that supports the X.75 protocol.
If unsuccessful try again  –  define  the  time  interval  between  the  PBX
connection attempts in case of failure (PBX switch-off or restart).
Connect as – here define the login and password data for a secured PBX access.