Connect - the relay is activated unless activated before.
Disconnect - the relay is deactivated unless deactivated before.
Connect pulse - the relay is activated for the time defined in the Pulse
parameter and then re-deactivated. If activated earlier, it is
width [ms]
only deactivated at the end of the pulse.
Disconnect pulse - the relay is deactivated for the time defined in the
parameter and then re-activated. If deactivated earlier,
Pulse width [ms]
it is only activated at the end of the pulse.
Action at hang up - this section defines the action to be executed upon hang up
of a call coming to this routing object.
None - the relay does not respond to the hang up.
Connect - the relay is activated unless activated before.
Disconnect - the relay is deactivated unless deactivated before.
Connect pulse - the relay is activated for the time defined in the Pulse
parameter and then re-deactivated. If activated earlier, it is
width [ms]
only deactivated at the end of the pulse.
Disconnect pulse - the relay is deactivated for the time defined in the
parameter and then re-activated. If deactivated earlier,
Pulse width [ms]
it is only activated at the end of the pulse.
Action after timeout/tone - this section defines the action to be executed after
the
expiry or after
.
Timeout
Playing whole tone
None - the routing object does not respond to the timeout expiry or the
end of the played tone.
Hang up - after the timeout expiry or playing the whole tone, the call is
hung up in the routing object with cause no. 16 - normal call clearing.
Call destination - after the time expiry or playing the whole tone, the call
is routed as configured in the
option.
Destination
Play whole tone - use this option to enable playing of the whole tone
independently of the preset time limit.
Destination - use this section to define the next routing destination after
the time limit or playing the whole tone.
Connect by time conditions - use this option to enable the relay activation
according to the selected time conditions. The relay is activated whenever one
time condition at least is valid. If this option is not checked, the preset time