3.2 Cornet

Cornet is a digital virtual port for the StarPoint key phones with proprietary signalling
(UPN  interface).  The  Stack  tag  provides  limited  configuration  capacities  only.  The
parameters are divided into logical sections according to their respective functions. For
the StarPoint configuration parameters refer to the Softphone subtag of the Properties
tag. For more details on Softphone extensions refer to Chapter 

.

Setting Properties

Virtual port status

The  upper  menu  field  displays  information  on  the  stack  type  and  its  current  status
including  information  on  the  L1  and  L2  states,  increased  bit  error  rate  or
nonsynchronous L1.

Digital interface parameters

Interface type – the parameter cannot be configured. It only shows the type of
interface.
Interface mode – this parameter is set to NT and cannot be reconfigured. Thus,
cross–connecting lines cannot be made using these ports.
Bus mode  –  this  parameter  is  always  set  to  PTP  and  cannot  be  reconfigured.
This port is used for one terminal only.
Enabled channels – use this parameter to enable selected interface channels. If
none is enabled, the interface cannot be used and behaves as if it was busy.
Keep L1 active  –  check  this  option  to  make  the  PBX  keep  the  interface  active
automatically.
Inactive L1 as error – use this option to activate a caution about the first layer
being  inactive.  This  is  indicated  by  a  red  exclamation  mark  on  the  port  in  the 

 menu and a red text in the upper stack status field.

Hardware – Boards

Set BER – select BER as error to enable acceptable BER range parameters. If the
BER rate gets over the 

, a red exclamation mark appears on the

BER error level

port  in  the 

  menu  and  a  red  text  is  displayed  in  the  port

Hardware – Boards

status field. This error status gets changed after the BER value falls below the 

. The interval between these two values represents hysteresis. The

BER OK level
BER  values  are  entered  in  an  exponential  format  (e.g.  3e–5  means  3  errors  in
100,000 bits).

Master terminal

Type – shows the type of the StarPoint terminal connected.
Firmware – shows the current firmware version of the terminal connected.
Extenders  –  shows  information  on  the  active  extenders  of  the  terminal
connected.

Slave terminal

Type – shows the type of the StarPoint terminal connected.
Firmware – shows the current firmware version of the terminal connected.
Extenders  –  shows  information  on  the  active  extenders  of  the  terminal
connected.