Table 5-4 port detail view page fields – HP HSG Array Controller User Manual
Page 98
5-18 StorageWorks Fibre Channel Storage Switch User's Guide
Compaq Confidential – Need to Know Required
Writer: Bill Reitz Project: StorageWorks Fibre Channel Storage Switch User's Guide Comments:
Part Number: AA-RHBYA-TE 135267-001 File Name: f-ch5 Managing the Switch over the Web Last Saved On: 4/7/99 12:36 PM
Table 5-4
Port Detail View Page Fields
Field
Description
Port Number
The port number.
Port Status
The port state follows the GBIC type. The possible port states include:
■
No_Card no card present in this Switch slot
■
No_Module no GBIC module in this port
■
No_Light the module is not receiving light
■
No_Sync the module is receiving light but is out of sync
■
In_Sync the module is receiving light and is in sync
■
Laser_Flt the module is signaling a laser fault (defective GBIC)
■
Port_Flt the port has been marked faulty (defective GBIC, cable, or
device)
■
Diag_Flt the port failed diagnostics (defective G_Port or FL_Port card
or motherboard)
■
Online the port is up and running
■
Lock_Ref the port locking to the reference signal
Port Type
The port type (E_Port, G_Port or FL_Port).
Port Module (or GBIC
Module)
The GBIC type follows the port number. The four GBIC types include:
■
no GBIC present
■
sw shortwave GBIC
■
lw longwave GBIC
■
cu copper GBIC
Port World Wide Name
The World Wide Name for this port.
Interrupts
Total number of interrupts.
Unknown
Number of unknown interrupts.
Lli
Number of low level interface (LLI) interrupts.
Proc_rqrd
Number of interrupts with processing (CPU) required.
Timed_out
Number of timed out interrupts.
continued