portRegTest

Figure B-45 shows

theportRegTest

command which is used to check

each register located on the motherboard and interface card(s) chips. Registers
are set under firmware control and are used to control the hardware route
selection and other internal hardware functions.

This command may not be executed on an operational Switch. Before issuing

portRegTest

, disable the Switch using the

switchDisable

command

This test validates that all registers can be successfully addressed.

admin> portRegTest

Running Port Register Test .... passed.

value = 0 = 0x0

Figure B-44. portRegTest Command Example

ramTest

Figure B-46 shows the ramTest command which is used to check CPU RAM
memory. The Switch ships with 2MB of CPU RAM. This test validates proper
memory function. If this test fails, replace the memory module on the CPU
card as described in Replacing a Memory Module.

admin> ramTest

Running System DRAM Test ...... passed.

value = 0 = 0x0