beautypg.com

HP HSG Array Controller User Manual

Page 215

background image

Telnet Commands B-75

Compaq Confidential – Need to Know Required

Writer: Bill Reitz Project: StorageWorks Fibre Channel Storage Switch User's Guide Comments:

Part Number: AA-RHBYA-TE 135267-001 File Name: i-appb Telnet Commands Last Saved On: 4/7/99 12:36 PM

Table B-15

diagShow command field descriptions

Field

Description

Diag Port Status

The port status

port#

The port number

diags

Possible values include OK, BAD.

state

Possible values include UP (online), DN (offline.)

st0-16

The tested chips. The display shows the
diagnostics frames are transmitted and received
and Low Level Interface counts (LLI_errs).

Note that port 16 is the embedded port.

Central Memory Status

The central memory status. Possible values include
OK, FAULTY.

Total Diag Frames Tx

The total diagnostics frames transmitted (Tx) since
boot. This number usually corresponds to the total
frames received (Rx) but may differ because of
failure modes.

Total Diag Frames Rx

The total diagnostics frames received (Rx) since
boot. This number usually corresponds to the total
frames transmitted (Tx) but may differ because of
failure modes.