HP HSG Array Controller User Manual
Page 215
Telnet Commands B-75
Compaq Confidential – Need to Know Required
Writer: Bill Reitz Project: StorageWorks Fibre Channel Storage Switch User's Guide Comments:
Part Number: AA-RHBYA-TE 135267-001 File Name: i-appb Telnet Commands Last Saved On: 4/7/99 12:36 PM
Table B-15
diagShow command field descriptions
Field
Description
Diag Port Status
The port status
port#
The port number
diags
Possible values include OK, BAD.
state
Possible values include UP (online), DN (offline.)
st0-16
The tested chips. The display shows the
diagnostics frames are transmitted and received
and Low Level Interface counts (LLI_errs).
Note that port 16 is the embedded port.
Central Memory Status
The central memory status. Possible values include
OK, FAULTY.
Total Diag Frames Tx
The total diagnostics frames transmitted (Tx) since
boot. This number usually corresponds to the total
frames received (Rx) but may differ because of
failure modes.
Total Diag Frames Rx
The total diagnostics frames received (Rx) since
boot. This number usually corresponds to the total
frames transmitted (Tx) but may differ because of
failure modes.