Pencil–mark the mounting bracket holes on each side of the rack with an
M.
3.
Slide a clip nut over the marked hole on each rear rail (Figure 2–3).
4.
Attach a mounting bracket to the rails on each side of the rack and
secure each bracket with three 10–32x5/8 SEMS screws; tighten the
screws at the front before you tighten the one at the rear.
5.
Go to the section entitled Attaching the Slide Brackets to the Switch.
2
1
1
SHR-1380
2
Mounting bracket; Clip nut
Figure 2-3. Installing the Mounting Brackets in a RETMA 41U Rack
Attaching Mounting Brackets in a RETMA 42U or
Compaq Rack
You can mount the Switch in this rack from either the front or the rear of the
rack. Perform the following steps:
1.
Position the mounting template against the front and rear vertical rails
(Figure 2–2), first on one side of the cabinet and then on the other side;
make sure the template is parallel from front–to–rear.
IMPORTANT: In a rack–front installation the template front should be positioned against
the front rail; in a rack–rear installation the template front should be positioned against
the rear rail.
2.
Pencil–mark the mounting bracket holes on each side of the rack with
an M.