HP HSG Array Controller User Manual
Page 164
B-24 StorageWorks Fibre Channel Storage Switch User's Guide
Compaq Confidential – Need to Know Required
Writer: Bill Reitz Project: StorageWorks Fibre Channel Storage Switch User's Guide Comments:
Part Number: AA-RHBYA-TE 135267-001 File Name: i-appb Telnet Commands Last Saved On: 4/7/99 12:36 PM
Table B-6
flashShow Command Field Descriptions
continued
Field
Description
df_size
The receive data field size.
r_a_tov
The resource allocation time out value.
e_d_tov
The error detect time out value.
op_mode
Operating mode.
vc_link_ctl
Virtual channel link control.
vc_class2
Virtual channel class 2.
vc_class3
Virtual channel class 3.
vc_multicast
Virtual channel multicast.
vc_priorities
The numbers displayed show the priorities assigned to each of
the Switch’s virtual channels. Positions 1 and 2, starting at the
left of the display, are fixed and displays 0 or 1.
The first position a 0 shows and indicates that this virtual
channel, assigned to handle internal Switch traffic, has the
highest priority. This priority value cannot be changed.
The second position, indicated with a 1, shows the priority
assigned by the virtual channel link control.
The third through eighth positions they can have only a 2 or a 3
indicating that the channel gives priority to either Class 2 frame
traffic or to Class 3 frame traffic.
vc_pid_map
Virtual channel Port ID time out map.
frm collection
Supports 2 frame collection methods
, piling and bundling.
alt bb_credit
This is the value used in an NL_Port's FLOGI.
continued