Writer: Bill Reitz Project: StorageWorks Fibre Channel Storage Switch User's Guide Comments:
Part Number: AA-RHBYA-TE 135267-001 File Name: i-appb Telnet Commands Last Saved On: 4/7/99 12:36 PM
NOTE: When running the Spin Silk Test, you must set the operating mode value to 0 or 1.
Modes 2 and 3 do not send out the ELP used to discover Switches. If the ELP is not sent,
the Switch does not know the port is connected to another port on the same Switch and
the test fails. Using operating mode 0 when running spinSilk is preferred.
If an error is encountered during the test, the error is displayed during the
Telnet session. Refer to SpinSilk Test Error Messages.
The spinSilk test is used to transfer frames internally at the maximum
hardware rated speed.
admin> spinSilk
Running Spin Silk .............
One moment please ........
One or more ports is not active,
please doublecheck fibres on all ports.
Port SNMP Physical Flags
-------------------------------
0: Offline Port_Flt PRESENT L_PORT LED
1: Offline No_Module PRESENT L_PORT CBL_LB LED
2: Offline No_Light PRESENT L_PORT CBL_LB LED
3: Offline Port_Flt PRESENT L_PORT LED
4: Offline No_Module PRESENT G_PORT LED
5: Offline No_Module PRESENT G_PORT LED
6: Offline No_Module PRESENT G_PORT LED
7: Offline No_Module PRESENT G_PORT LED
8: Offline No_Light PRESENT G_PORT LED
9: Offline No_Light PRESENT G_PORT LED
10: Offline No_Light PRESENT G_PORT LED
11: Offline No_Light PRESENT G_PORT LED
12: Offline No_Light PRESENT G_PORT LED
13: Offline No_Light PRESENT G_PORT LED
14: Offline No_Light PRESENT G_PORT LED
15: Offline No_Light PRESENT G_PORT LED
16: Testing In_Sync PRESENT ACTIVE G_PORT INT_LB
value = 65536 = 0x10000
Figure B-47. spinSilk Command Example 1