HP HSG Array Controller User Manual
Page 231
Telnet Commands B-91
Compaq Confidential – Need to Know Required
Writer: Bill Reitz Project: StorageWorks Fibre Channel Storage Switch User's Guide Comments:
Part Number: AA-RHBYA-TE 135267-001 File Name: i-appb Telnet Commands Last Saved On: 4/7/99 12:36 PM
The command syntax is
nbrStateShow
to list the
neighbor on the specified port.
admin> nbrStateShow 1
Local Domain ID: 3
Local Port Domain Remote Port State
-------------------------------------------------------
1 2 1 NB_ST_FULL
value = 1 = 0x1
Figure B-59. nbrStateShow Command Example
Table B-21
nbrStateShow Command Field Descriptions
Field
Description
Local Port
Corresponds to idbNo in the neighbor data
structure.
Domain
Corresponds to nghbId in the neighbor data
structure.
Remote Port
Corresponds to remPort in the neighbor data
structure.
State
The neighbor’s current state. Its value must be
NB_ST_FULL for the ISL to forward frames to the
adjacent Switch. Other values may be transitory,
however if a value is retained for more than ten
seconds, contact Technical Support.