Error log – HP HSG Array Controller User Manual
Page 60
3-26 StorageWorks Fibre Channel Storage Switch User's Guide
Compaq Confidential – Need to Know Required
Writer: Bill Reitz Project: StorageWorks Fibre Channel Storage Switch User's Guide Comments:
Part Number: AA-RHBYA-TE 135267-001 File Name: d-ch3 Managing the Switch Last Saved On: 4/7/99 11:59 AM
The temperature readings are shown at a rate of one reading per second on the
front panel. Readings obtained during a Telnet session are single reading made
at command execution.
Error Log
Selecting
Error Log
, then pressing
01 Feb 12 08:48:29 (23)
Err SENSOR-FAILED-3
The error log stores the last 30 error types sensed by the Switch. The front
panel display shows:
■
Error number (01-30)
■
Date and time of the last occurrence each error type was sensed
■
Total number of occurrences of each error type
■
Error type
■
Error level (0-4)
0–Panic (when this level is reached, the Switch automatically reboots and the
display no longer shows the error)
1–Critical
2–Error
3–Warning
4–Debug
In the sample above, the first line shows that this is the first error (01) found
on Feb 12 08:48:29 and had (23) occurrences. The second line shows that the
error type is SENSOR-FAILED with a severity level of 3 (warning).
NOTE: The error occurrence count, shown in brackets at the end of the first line, does not
appear until the error occurrence is higher than one.