HP HSG Array Controller User Manual
Page 206
B-66 StorageWorks Fibre Channel Storage Switch User's Guide
Compaq Confidential – Need to Know Required
Writer: Bill Reitz Project: StorageWorks Fibre Channel Storage Switch User's Guide Comments:
Part Number: AA-RHBYA-TE 135267-001 File Name: i-appb Telnet Commands Last Saved On: 4/7/99 12:36 PM
admin> portLoopbackTest
Running Port Loopback Test ....
Diags: (Q)uit, (C)ontinue, (S)tats, (L)og: s
Diagnostics Status: Sun May 18 21:49:58 1970
port#: 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
diags: OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK
state: UP UP UP UP UP UP UP UP UP UP UP UP UP UP UP UP UP
fl0: 311 frTx 311 frRx 0 LLI_errs.
fl1: 311 frTx 311 frRx 0 LLI_errs.
fl2: 311 frTx 311 frRx 0 LLI_errs.
fl3: 311 frTx 311 frRx 0 LLI_errs.
st4: 311 frTx 311 frRx 0 LLI_errs.
st5: 311 frTx 311 frRx 0 LLI_errs.
st6: 311 frTx 311 frRx 0 LLI_errs.
st7: 311 frTx 311 frRx 0 LLI_errs.
st8: 311 frTx 311 frRx 0 LLI_errs.
st9: 311 frTx 311 frRx 0 LLI_errs.
st10: 311 frTx 311 frRx 0 LLI_errs.
st11: 311 frTx 311 frRx 0 LLI_errs.
st12: 311 frTx 311 frRx 0 LLI_errs.
st13: 311 frTx 311 frRx 0 LLI_errs.
st14: 311 frTx 311 frRx 0 LLI_errs.
st15: 311 frTx 311 frRx 0 LLI_errs.
st16: 311 frTx 311 frRx 0 LLI_errs.
Central Memory OK
Total Diag Frames Tx: 5287
Total Diag Frames Rx: 5287
Diags: (Q)uit, (C)ontinue, (S)tats, (L)og: q
aborted
value = 1048576 = 0x100000
Figure B-43. portLoopbackTest Command Example