Table B-18

interfaceShow Command Field Descriptions

Field

Description

idbP

The port number.

nghbP

The neighbor (adjacent) Switch’s port

ifNo

The port number. It should be identical to the value specified in the
command line.

cost

The cost of sending a frame over the ISL connected to this port. The
value 1000 indicates a 1 Gbps link.

delay

The conventional delay incurred by a frame transmitted on this ISL.
It is required by the FSPF protocol, and is a fixed value.

upCount

The number of times this interface initialized (the transition number
from an offline to E_Port state).

iState

The current interface state. It must be UP in order for the ISL to
forward frames to the adjacent Switch.

state

The current neighbor state. Its value must be NB_ST_FULL for the
ISL to forward frames to the adjacent Switch. Other values may be
transitory, however if a value is retained for more than ten seconds,
contact Technical Support.

nghbCap

Neighbor capabilities has a value of 0.

nghbId

The neighbor (adjacent) Switch’s domain ID.

idbNo

The port number and it should be equal to No.

remPort

The port # on the remote Switch connected to this port.

nflags

Internal flags for the Neighbor Finite State Machine.

initCount

The number of times this Neighbor Finite State was initialized.