diagShow
Figure B-52 shows the
diagShow
command which summarizes the
diagnostics results run since the Switch was last booted, including POST
results. The fields are described in Table B-15.
NOTE: This command shows an FL_Port as being offline if you are running cross port
connected testing, the reason is that you can have only one Principle per Switch. The
FL_Port to FL_Port testing still proceeds even though this is NOT the correct way to
connect FL_Ports.
The command also allows you to loop on the command. For example,
diagShow 4 executes diagShow every 4 seconds continuously unless stopped
by pressing Return. This may be used to isolate a bad GBIC. A port with a
changing LLI_errs value is prefixed by "**" in the display. The example
below shows 2 passes, the first pass without an error on the line st11 (in bold)
and the second pass shows an error on the line st11 (in bold). The screen
shows:
■
Each port number diagnostic status (OK/BAD) and port state (up
(online)/down (offline))
■
Frames transmitted (frTx) frames received (frRx) and Low Level
Interface error count (LLI_errs) for active ports
■
Central memory status (OK/FAULTY)
■
Total diagnostics frames transmitted (Tx) and received (Rx) since boot,
which are normally the same, but may differ because of failure modes.
NOTE: Port 16 is the embedded port.