nbrStateShow
Figure B-59 and Figure B-60 shows the
nbrStateShow
command which
displays neighbor's summary information. This information can also be
retrieved using
interfaceShow
. The command provides essential
information to determine the Fabric topology in a concise way. By using this
command, you can discover the domain ID of all Switches directly connected
to the local Switch, and the port number on the local and remote Switch. The
fields are described in Table B-19.
With no parameters it shows the neighbor's state summary for all the neighbors
instead of neighbor connected to port 0 only.
The command syntax is nbrStateShow to list all neighbors.
admin> nbrStateShow
Local Domain ID: 1
Local Port Domain Remote Port State
-------------------------------------------------------
0 2 0 NB_ST_FULL
1 2 1 NB_ST_FULL
2 2 2 NB_ST_FULL
4 5 4 NB_ST_FULL
5 5 5 NB_ST_FULL
7 5 6 NB_ST_FULL
value = 1 = 0x1